LoRad Connectors
SUPRA
LoRad SW Series
A Series of Patented Mains Plugs
SW is a series of mains plugs for 110-240V, safety approved Hospital Grade and
Audio Grade. Accepts large cable diameters. Easy to assemble, no loose screws,
nothing to slip onto the cable before termination.
Available for American, British and European standards.
Design and patent: Tommy Jenving..
|
 |
SW-EU Male Plug
16A Schuko, European Standard. Gold plated pins.
Accepts a cable dia. up to mm.
Mates also the French standard.
|

|
|
SW-US Male
Plug
15A. Hospital Grade.
Nema 15 American standard. Gold plated pins.
Accepts a cable dia. up to mm.
|


|
|
SWF-10 Female Connector
10A. IEC-320. Gold plated terminations.
Accepts a cable dia. up to mm.
Fits MCH10 male chassis connector. |

|
|
SWF-16 Female
Connector
16A. IEC-320. Gold plated terminations.
Accepts a cable dia. up to mm. |

|
 |
MC-BS Mains Plug
Male
Gold plated pins. Takes cable diameter up to 11mm.
Available for different standards:
MC-BS for British standard.
|

|
|
MC-BS Male Connector
with Fuse
13A, British standard BS1363A. Gold plated pins.
Accepts a cable dia. up to mm. |

|
|
The Lorad Concept
LoRad is a mains flex with patented screening for connection of audio equipment
to 230V mains. The screening minimizes the interference from electric
alternating fields, protecting from both radiation and pick-up. For cancelling
of magnetic alternating fields the LoRad is cabled with a short pitch twisting.
LoRad, the only approved screened mains flex. Owing to the patented design the
drain wire is eliminated and instead the screen is automatically connected to
earth via a green semi-conductive plastic on the earth conductor. This enables
the cable to pass the flex test of 2x30,000 bending strokes without damage, for
safety approval, whereas a drain wire would cut through the insulations during
the test. The LoRad is very flexible owing to the multiwire conductors. Each
conductor is made of 320 tin plated copper wires.
- LoRad stands for Low Radiation of electric and magnetic
alternating fields
- The screen protects your equipment from radiated mains
noise and from RF oick-up.
- Short pitch twisting of the cores cancels the magnetic
alternating fields.
- This will result in a cleaner sound and more accurate
transients.
The screen is ground connected via
a semi-conductive PE on the earth conductor. No drain wire needed. The green
part of the yellow/green earth conductor is of two different green nuances.
Please be aware that the darker green plastic is the semi-conductive part. It
must not touch any live part of the cord set. |